Neware Techonology ltd.
|
Price: | 1.0 USD |
Payment Terms: | T/T,WU |
Place of Origin: | Guangdong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Battery discharge charge and capacity tester BTS-5V60Ah
The Battery discharge charge and capacity tester software can set working steps and working parameters, working modes of each step flexibly. Working modes includes constant current discharge, constant current charge, constant voltage charge, rest, GOTO, (internal resistance measurement). Each working modes can set voltage, current, time, capability, negative voltage slope, and other limit conditions, the relation of which is "logic or". When the present limit conditions are met, the system will continue next working mode automatically. The set program can be saved and opened in the form of Schedule.
Model: | BTS- | 5 | V | 60 | A | Material Code: | CT-4008 | -5V60A | - | NTA | - | P | ||||
Description | Product Specification | |||||||||||||||
AC Input | AC 220V ±10% / 50Hz | |||||||||||||||
Power | 4480 | W | ||||||||||||||
Resolution | AD: 16bit; DA: 16bit | |||||||||||||||
Impedence Input | ≥1MΩ | |||||||||||||||
Voltage | Measuring Range | Charge: 25mV~5V | Dischrge: 25mV~5V | |||||||||||||
Discharge Min Voltage | 2.5V | |||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Current | Range | Charge: 300mA~60A Discharge: 300mA~60A | ||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Power | Output Power Per Channel | 300W | ||||||||||||||
Stability | ±0.2% of FS | |||||||||||||||
Time | Rise Time | 20ms (10%FS~90%FS) | ||||||||||||||
Step Time | ≤ (365*24) hours/step | Time Format 00:00:00:000 ( h:min:s:ms ) | ||||||||||||||
Aux Channel | Aux Input | Temperature | ||||||||||||||
Temperature | ﹣25℃~110℃ | |||||||||||||||
Temperature Accuracy | ±2℃ | |||||||||||||||
Temperature Resolution | 0.1℃ | |||||||||||||||
Voltage Range | ||||||||||||||||
Voltage Accuracy | ||||||||||||||||
Data Accquisition | Intervals | Time Interval Δt: (100ms~60000s) | ||||||||||||||
Voltage Interval ΔU: (10mV~5V) | ||||||||||||||||
Current Interval ΔI: (120mA~60A) | ||||||||||||||||
Frequency | 10Hz | |||||||||||||||
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC | ||||||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||||||
Aux: Temperature | ||||||||||||||||
Discharge | Modes of Operation | CCD, CPD, CRD | ||||||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||||||
Aux Channel: Temperature | ||||||||||||||||
Pulse | Charge | CCC | ||||||||||||||
Discharge | CCD | |||||||||||||||
Minimum Pulse Width | 500ms | |||||||||||||||
Automated Switch | Automated switch from charge to discharge for each pulse | |||||||||||||||
End Condition | Voltage, Test Time | |||||||||||||||
Cycle | Cycles | Max 65535 | ||||||||||||||
Steps | 254 | |||||||||||||||
Nested Fuction | Max three levels of loops | |||||||||||||||
Protective Function | Software | ● Power-off data protection | ||||||||||||||
● Off-line Operating | ||||||||||||||||
● Main Channels: user-defined safety(upper and lower)tolerance of current, voltage and delay time | ||||||||||||||||
●Aux Channels: User-defined safety (upper and lower) tolerance of temperature | ||||||||||||||||
Hardware | Reverse-connecting protection | |||||||||||||||
Channel Features | Independent pairs of closed loops for constant current source and constant voltage source | |||||||||||||||
Channels | Independent Control | |||||||||||||||
Detection and Sampling | 4-wire Connecting | |||||||||||||||
Noise Density | <85dB | |||||||||||||||
Data Management | MYSQL Database | |||||||||||||||
Communication Means | TCP/IP Protocol | |||||||||||||||
Export Formats | EXCEL2003,2010,TXT,Graph | |||||||||||||||
Communication Interface | Ethernet Port | |||||||||||||||
Number of Channels Per Cabinet | 8 | |||||||||||||||
Assignable Aux Temperature Per Channel | Max 248 | |||||||||||||||
Operating Environment | ||||||||||||||||
Description | Product Specification | |||||||||||||||
Operating Temperature | 0℃~40℃ | |||||||||||||||
Storage Temperature | -10℃~50℃ | |||||||||||||||
Operating Humidity | ≤70% RH | |||||||||||||||
Storage Humidity | ≤80% RH |
Our marital supplier:
Our customer :
Our advantages:
All kinds of types are manufactured for a range of current from 1mA to 1000A, a range of voltage from 5V to 500V to meet customers' special needs. We also provide the BTS which can test the voltage of 0 V or even lower.
1.Reasonable Price, standarbale and Reliable Product.
2.Improve the quality and life expectancy of your products
3.Work Performance more effective and efficacy
4.17years innovation guarantees you a in better future.
Warranty and Customer Service:
Neware warrants its equipment for 1 year from shipment, to be free from defects in workmanship and material. For some other consumptive materials, like battery clamps, we provide a 3-month warranty. This warranty, including customer service support and software licenses, is not transferable. Meanwhile, we provide lifetime software update
service to help your equipment optimized in its best status.
We provide below customer services:
1.Free Technical Training.
2.Free Service Call Service.
3.Testing Service.
4.Calibration Service.